The generator employs a stator assembly having a dual set of AC power windings and a 3-
wire AC connection system. Each stator AC power winding supplies 120 volts AC. When
the two windings are connected in series, a 240 volt AC output results.
Grounding the generator
Make sure that the generator is properly grounded at all times!
Proper grounding of the generator will help prevent electric shock in the event of a ground
fault condition in the generator or in electrical devices connected to the generator.
Proper grounding also helps to dissipate static electricity, which often builds up in
ungrounded devices.
Do not connect the ground wire to any pipe that carries flammable or explosive
substances. Fire or an explosion may result.
The National Electrical Code requires that the frame and external electrically
conductive parts of this generator be properly connected to an approved earth ground.
Local electrical codes may also require proper grounding of generator.
However, local codes may vary widely. Consult with a local licensed and experienced
electrician for grounding requirements in your area.
Generator 3 wire AC Diagram
1. Main circuit breaker
2. Dual stator AC power windings