Pulsing FiberAlert
Pulsing FiberAlert minimizes the problems associated with the loss of one strand of
fiber. If a strand is unavailable, the device at the receiver end notes the loss of link.
The device will stop transmitting data and start sending link pulses. Until a valid link
is received, the fiber link LED will be OFF on the device on the receiver side of the
fiber strand with the fault while the fiber Link LED on the other unit will blink.
Pulsing FiberAlert notifies a local site administrator of a fault, allowing quick
determination of where a cable fault resides.
NOTE
Pulsing FiberAlert can be enabled on BOTH sides of a conversion.
Using FiberAlert and LinkLoss (All Models without LFPT Capability)
The following chart provides an overview of the troubleshooting features, their
functionality and the recommended settings for a pair of media converters in a typical
central/main site to remote site application:
LinkLoss / FiberAlert Comparison
Feature Fault Location Disabled LED Enable at:
FX LinkLoss Fiber Twisted Pair Main Site Only
TX LinkLoss Twisted Pair Fiber Remote Site Only
FiberAlert Fiber Fiber Remote Site Only
For more information about these features, refer to their specific sections.
Configuring LinkLoss and FiberAlert
Configure LinkLoss and FiberAlert with separate 3-pin jumper blocks or DIP Switches
located at various positions depending on module and board type. See the table to
determine what features the module offers as well as the jumper locations and
ON/OFF positions.