Instruction manual

The twisted pair port on the iMcV-Giga-MediaLinX includes AutoCross, a feature
that automatically selects between a crossover workstation or pass-through
connection depending on the connected device.
Installing iMcV-Giga-MediaLinX Modules
The iMcV-Giga-MediaLinX installs in any IMC Networks’ chassis, each requiring
one slot.
To install an iMcV-Giga-MediaLinX module:
Step Action
1 Remove the blank brackets covering the slots where the module is to be
installed (if present) by removing the screws on the outside edges of the
bracket.
2 Slide the module into the chassis via the card guides until the module is
seated securely in the connector.
3 Secure the module to the chassis by tightening the captive screw.
4 Save any “blanks” removed during installation for future use should the
configuration requirements change.
Installation Troubleshooting
During installation, test the fiber and twisted pair connections with all
troubleshooting features disabled. If desired, enable these features just
before installation. This will reduce the features’ interference with
testing.
Any testing of the module should be performed in an unmanaged
environment. Either test in an unmanaged chassis or disable
management in a managed chassis, where possible.
LNK LEDs only function after both twisted pair and fiber connections
are established.
If using a high powered device (for long distance installations) for a short
distance installation, the fiber transmitters may overdrive the receivers
and cause data loss. In such a case, add an optical attenuator to the
connection.
2