Instruction manual
10
Installation Troubleshooting
General Troubleshooting
•
During installation, first test the fiber and BNC connections with all
troubleshooting features disabled; then enable these features, if desired, just
before final installation. This will reduce the features’ interference with
testing.
•
When working with units where the features cannot be disabled, you must
establish BOTH your BNC and fiber connections; the NO LNK LEDs should
not be lit (i.e. NO LNK LED not lit = good connection, NO LNK LED lit =
problem).
•
To test a media converter by itself, first make sure you have an appropriate
fiber patch cable, then follow these steps to test:
1.
Connect the media converter to the BNC device with a coax cable.
2.
Loop a single strand of fiber from the transmit port to the receive port of
your media converter.
3.
Verify that you have a valid connection for both the BNC and fiber ports
on your media converter.
•
If there is trouble with link connectivity, make sure the connection is made
using 75W Coax cable.
Specifications
Power Consumption (Typical)
0.550 Amps @ 5 V
Operating Temperature
32° to 122° F (0° to 50° C)
Storage Temperature
0° to 160°F (-20° to 70° C)
Humidity
5 to 95% (non-condensing); 0 to 10,000 ft. altitude
Dimensions
4.19” x .78” x 2.75”
(106.4 mm x 19.81 mm x 69.85 mm)