802.1p Base Pri
Set the level of 802.1p base priority (3 or 4).
The IE-MiniFiberLinX-II has two outgoing queues; one for
high priority traffic and one for low priority traffic. If the Base
VLAN Priority is 4 for example, 0-3 are low priority and 4-7
are high priority. If the Base VLAN Priority is changed to 3,
0-2 are low priority and 3-7 are high priority.
Serial Configuration/Telnet Session
Access to the IE-MiniFiberLinX-II can be managed by typing accounts and pressing
Enter
from the command screen.
On the screen that appears, press
A
to add a user, entering the user’s information in
the appropriate fields. To delete a user, press
D
for the user selected. Pressing any
other button will exit this screen.
NOTE
User rights only allow viewing of status/settings but not changing of settings.
To log onto the unit through the serial port, connect a PC to the IE-MiniFiberLinX-II
using the included adapter. Set the computer/terminal for VT-100 emulation, with
the following settings: 38.4K baud, 8 data bits, 1 stop bit, no parity, no FlowControl.
Enter the User Name and Password as admin (which is the default setting), when
connecting through Telnet/HyperTerminal. A new User Name and Password should
be set after signing on the first time.
Assign the IE-MiniFiberLinX-II an IP address before using a Telnet session (
the default
IP address is 10.10.10.10
). All configurations performed using the serial port can
also be performed using Telnet. Multiple accounts can be assigned with individual
names and passwords.
Each account can be assigned one of the following authority roles:
User
This role can only see status, change a password, and
reboot
.
Operator
This role can perform User role functions and change settings.