Instruction manual

5
Command List
I
= Enter new
Saved Parameter Values
P
= Change the
Password
*
T
= Enter new
Trap Destinations
K
= Remove
All
Trap Destinations
C
= Create
SNMP Community Strings
U
= Delete All
SNMP Community Strings
E
=
End
the session*
Reboot
= Reboot the unit (may result in short data loss)
D
= Enable or disable
DHCP
Space Bar
= Opens the device specific configuration options screen.
*
Individuals with User-level rights can only view port status and port settings,
change their password, end a session, and reboot the unit.
NOTE
It is necessary to reboot the IE-MultiWay after making any modifications to the Saved Values
for the changes to take effect. To reboot, type
Reboot
at the prompt on the Main
Configuration screen.
Assigning IP Information
To modify the Saved Parameter Values (i.e., assign IP address and subnet mask),
press
I
. The system prompts for the IP address and subnet mask for the connected
device. Press
Enter
after each entry. A default gateway can also be assigned, or press
Enter
to skip. When finished, press Enter, then type
reboot
for changes to take effect.
The Current Values can only be saved and acted on after the IE-MultiWay has been
successfully rebooted.
Password Protection for Serial Port Connections
Passwords have the following requirements:
The password must be between 1 and 8 characters long
The password consists of a combination of any ASCII characters except spaces
Passwords are case sensitive
Password protection is provided for the serial configuration process by pressing
P
on
the main configuration screen. Enter a password, keeping in mind that passwords are
case-sensitive and must not exceed eight characters or include spaces, and press
Enter
. This password will be requested whenever logging on. To remove password
protection, select
P
and, instead of entering a password, press
Enter
.