User manual
Spare drIve
An unassigned hard drive can be assigned as a spare drive to replace a
failed hard drive in a RAID volume. One that is active and connected is
known as a “hot” spare drive.
• If a hard drive fails within a redundant RAID logical drive, and a
spare drive is present, the system uses the spare drive to rebuild
the array. Rebuilding begins automatically, and the spare drive
becomes part of the RAID logical drive.
• The spare can be dedicated to a specified logical drive, or
available to any logical drive when needed. If the spare is
revertible, it will revert to spare status after the failed hard drive
has been replaced and rebuilt.
• Some limitations on the use of spare drives with Imation
DataGuard Appliances:
✴ A spare drive cannot replace a failed hard drive in a RAID 0
logical drive because of the way data is written to hard drives
under RAID 0.
Storage > Spare Drive > Create Spare Drive (T5R)
CreAte SpAre drive
To assign a spare drive:
1. From the tab, click the menu item. If any spare drives are present,
they will be displayed in a list here.
2. Click the button.
3. Click on an available physical drive in the diagram to select it as a
spare drive. The ID numbers of the selected hard drive will appear
in the field below the diagram.
• Choose the options for the hot spare drive. The Revertible option
allows the spare drive to revert to hot spare status after a failed
hard drive is replaced and rebuilt. At this point, the used spare
drive will automatically be freed up and become a revertible spare
again after the reversion process, called transition, is initiated and
completed in the background.
• The can be Global or Dedicated. A Global spare is not dedicated
to a specific RAID array, and remains available as a hot spare for
any RAID array. A Dedicated spare drive is assigned to a specific
RAID array. For most users, a Global and Revertible configuration
is best.
• You can also enable when creating a spare drive. All these options
can be changed after the spare is created.
• Click the button to designate the drive as a hot spare.
To change settings for an existing spare drive, click on the button for
the listed spare and change the settings as desired.
Storage > Spare Drive > Create Spare Drive (R4)
38
✓