User manual

unInterruptIBle power Supply (upS)
Every DataGuard Appliance allows the use of an uninterruptible power
supply (UPS) that supports the APC UPS protocol. The UPS can
connected by USB or Ethernet. Follow these steps to configure UPS
features:
1. From the Device tab, click the UPS menu item.
2. Click the Setup button at the upper right.
3. Select your preferred settings for Interface, Power Off Threshold,
and IP Address.
4. To confirm and apply your selections, click Submit. To return to the
current settings, click Cancel.
UPS
Settings Description
Interface
Choose the type of UPS connected to the device, USB
or Network.
Power Off
Threshold
Select the Power Off Threshold option: Disabled,
Immediate, The reserve power reaches [choose
percentage] or After running [choose time to run].
IP Address
For Network UPS systems, enter the applicable IP
address.
Device > UPS > Setup
eXternal drIve
External hard drives can be attached to the DataGuard Appliance
through any of the five USB ports, and configured through the
External Drive menu in the Management Interface. A drive that has
already been formatted will connect automatically when powered
on and connected. If a drive has not been formatted, it must first be
formatted through the Format menu before it can be mounted.
Note: Refer to pages 3–6 for USB port locations on the
DataGuard R4 and T5R.
Device > External Drive
29