® Model No. IMSB63120 IMSG63120 Serial No. The serial number is on a plastic sign inside the spa behind the access panel. Record the serial number in the space above. USER’S MANUAL Access Panel QUESTIONS? If you have questions, or if there are missing parts, we will guarantee complete satisfaction through direct assistance from our factory. TO AVOID UNNECESSARY DELAYS, PLEASE CALL DIRECT TO OUR TOLL-FREE CUSTOMER HOT LINE.
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the following important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions. 10. Never insert any object into any opening. 11. Do not use breakable containers in or near the hydrotherapy spa. 2.
20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, telephones, televisions, and lights at least five feet away from the water. physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy. 21. A wire connector is provided on the electronics pack of the hydrotherapy spa to connect a minimum No.
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa.
Before You Begin Congratulations for selecting the new IMAGE® RENEW 631 hydrotherapy spa. The innovative RENEW 631 allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home. For your benefit, read this manual carefully before using the RENEW 631. If you have additional questions, please call our Customer Service Department tollfree at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays).
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your home.
Assembly Before beginning assembly, carefully read the following information and instructions: ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included): • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is operating. • One (1) phillips screwdriver • You may also need a small amount of soapy water. • During assembly, make sure that all parts are oriented as shown in the drawings.
3. Refer to the drawing on page 6 and locate the long access opening. Next, locate the two indicated gate valves inside the opening. Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves (refer to the inset drawing in step 2 on page 8). 3 Gate Valve Electronics Pack Make sure that the indicated collars are tightened. Locate the drain hose inside the opening.
Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat five adults. The spa holds 295 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment. Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONTROLS on page 12).
Spa Shell Diagram D D A P O O D P A P C K A B F E G I A M D H N L J A. The seven adjustable, directional jets can be pivoted to direct their water flow. L A O system. Never operate the spa without the suction covers in place. B. The adjustable, pulsing jet produces a soothing, pulsating massage action. L. The air controls determine the amount of air flowing through the spa jets during operation (see USING THE CONTROLS on page 12). C.
Using the Controls Air Controls 1, 2, and 3 Display Invert Button Pump Button 1 Display Invert Button: Turns the display 180°, allowing it to be read from inside or outside of the spa. Pump Button 2 Light Button Display Temperature Buttons flowing through the jets will increase; if the control is turned clockwise, the amount of air will decrease. Pump Button 1: Turns the spa jets labeled A (at the left) on and off. If the button is pressed once, the jets will run, providing gentle hydrotherapy.
Maintenance The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTAINING THE SPA COVER The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.
WATER CHEMISTRY ATTACHING AND REMOVING ACCESS PANELS CAUTION: The chemicals used to maintain the pH balance of the water and to sanitize the water can be dangerous. Always follow these basic guidelines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Do not exceed the recommended amounts of chemicals—follow the directions on the label closely. 4. Keep all chemicals out of the reach of children and pets. 5.
To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE 1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the pump access panel from the spa. 4. Remove the end of the drain hose from the spa. Remove the cap and attach a garden hose to the drain hose. The hydrotherapy spa is designed for year-round use. If you decide to store the spa for the winter, store it in a warm, dry location.
Troubleshooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE indoors and the room temperature is maintained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature. a.
b. A clamp or seal inside the pump compartment may be loose. Check inside the pump compartment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing. If you can identify the location of the leak inside the spa jet unit, tighten the clamp or replace the damaged seal. 12. SYMPTOM: THE CONSOLE DISPLAYS THE WORDS “COOL” OR “ICE” a. This is a normal function of the spa; no action is necessary.
Part List—Model No. IMSB63120/IMSG63120 Key No. Qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 1 2 1 1 2 1 32 1 4 1 1 6 4 1 1 1 2 4 2 1 1 2 8 8 4 9 2 2 1 4 8 9 1 3 9 6 Description R0602A Key No. Qty.
Exploded Drawing—Model No.
Ordering Replacement Parts To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 8 a.m. until 5 p.m. Central Time (excluding holidays).