¨ Model No. IMHS80081 Serial No. Write the serial number in the space above for reference. Serial Number Decal QUESTIONS? As a manufacturer, we are committed to providing complete customer satisfaction. If you have questions, or find that there are missing or damaged parts, we will guarantee complete satisfaction through direct assistance from our factory. TO AVOID UNNECESSARY DELAYS, PLEASE CALL DIRECT TO OUR TOLL-FREE CUSTOMER HOT LINE.
TABLE OF CONTENTS LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 WARNING DECAL PLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BEFORE YOU BEGIN . . . . . . . . . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the following important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions. must be maintained as explained in this manual (see page 13).
motor of this unit to connect a minimum No. 8 AWG (804 mm2) solid copper conductor between this unit and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet (1.52m) of the unit. the unborn child could be seriously harmed. 28.
WARNING LABEL IDENTIFICATION The warning labels shown below have been placed on the spa cover, printed inside the inflatable spa liner, and placed on the side of the spa jet unit of the hydrotherapy spa. Locate the labels and familiarize yourself with this information. The label on the side of the spa jet unit is an adhesive decal. If this decal is missing, or if it is not legible, please call our Customer Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m.
BEFORE YOU BEGIN Thank you for selecting the IMAGE¨ RENEW 800. The innovative RENEW 800 offers the features and quality of a traditional hot tub at an affordable price. Best of all, the RENEW 800 is fully portable, so you can take it wherever there is an electrical outlet. The RENEW 800 allows you to relax and unwind in the comfort of your own home. Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays).
CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you use the hydrotherapy spa inside or outside. We have listed several factors you may wish to consider as you decide where you want to use the hydrotherapy spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The hydrotherapy spa will increase the level of humidity in your home.
ASSEMBLY Before beginning assembly, carefully read the following information and instructions: ¥ Assembly requires the included air pump. ¥ Read each assembly step before you begin. ¥ Place all parts in a cleared area and remove the packing materials; do not dispose of the packing materials until assembly is completed. ¥ During assembly, make sure that all parts are oriented as shown in the drawings. ¥ Assembly requires two people. 1.
4. Remove the power cord from the Spa Jet Unit (13). 4 With the help of a second person, place the Spa Jet Unit (13) over the Side Panel (1) and the section of the Inflatable Spa Liner (9) which does not have the cushion. Be extremely careful not to tear the Inflatable Spa Liner (9) as you slide the Spa Jet Unit into place. 13 Power Cord 9 1 5. Before you fill the hydrotherapy spa, be sure that it is in the position you want, and that it can be easily serviced, if needed.
7. Place the Spa Cover (11) over the Side Panels (1, 2) and the Spa Jet Unit (13). Be sure that the Spa Cover is properly centered and that the straps on the Spa Cover line up with the straps extending from the slots in the Side Panels (1, 2). 7 11 Snap each of the six latches on the Spa Cover (11) into the buckles on the straps extending from the slots in the Side Panels (1, 2). 13 1, 2 Latches and Buckles USING THE HYDROTHERAPY SPA The hydrotherapy spa is designed for up to four adults.
STARTING THE HYDROTHERAPY SPA If the level is too low, add half of one of the ÒQUICK pHix It UPÓ packets to the water. Let the water circulate through the spa jet unit for five minutes. Test the pH level again. Repeat until the pH level is correct. Once you have tested the GFCI, you should verify the water flow from the pumping unit. Set the air control on the console to the lowest setting (see USING THE CONSOLE on the next page). The pumping unit will heat the water as it pumps.
DIAGRAM OF THE CONSOLE USING THE CONSOLE 70¡F to 104¡F. Use a medical or other accurate thermometer to check the temperature of the water. Refer to the console diagram above. The function of each console control is explained below: On/Off: Turns the spa jet unit on and off. When you first press the on/off button, the spa jet unit will run at low speed, providing gentle hydrotherapy. Press the button again and the jet unit will run at high speed, providing more intense hydrotherapy.
ment by removing the filter cover and the two filter cover screws and then pulling the filter from the spa jet unit. The spa jet unit features an automatic filter cycle and freeze protection. If the spa jet unit has not been operated for three hours, the pump will begin circulating the water for twenty minutes to filter any impurities. Also, if the water temperature falls below 40¡F, the pump will begin circulating and heating the water to prevent the water from freezing.
lines when handling the chemicals: 1. Always read and follow the directions on the label, unless directed otherwise. 2. Never mix different chemicals. 3. Keep all chemicals out of the reach of children and pets. 4. Do not exceed the recommended amountsÑfollow the directions on the label closely. 5. Keep all containers closed tightly when not in use. 6. Never add water to the chemicalsÑalways add the chemicals to the water as directed. 7. Always store chemicals in a cool, dry place.
b. The pump may have a bad bearing. Contact our customer service department. b. This problem is caused by excess air in the pump circulation system. Check to see if the primer cap is fully tightened. Prime the pump again and fully tighten the primer cap (see PRIMING THE SPA JET UNIT on page 10). 6. SYMPTOM: THE WATER DOES NOT HEAT a. The heater is attached to the pump in the spa jet unit. If the pump is operating, the water should heat. Cover the hydrotherapy spa with the spa cover.
ORDERING REPLACEMENT PARTS To order replacement parts, simply call our Customer Service Department toll-free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling: 1. The MODEL NUMBER of the product (IMHS80081). 2. The NAME of the product (IMAGE¨ RENEW 800). 3. The SERIAL NUMBER of the product (see the front cover of this manual). 4.
PART LISTÑModel No. IMHS80081 Key No. Qty.