® Model No. IMHS63100 Serial No. The serial number is on a plastic sign inside the spa behind the access panel. Record the serial number in the space above. USER’S MANUAL Access Panel QUESTIONS? As a manufacturer, we are committed to providing complete customer satisfaction. If you have questions, or if there are missing parts, we will guarantee complete satisfaction through direct assistance from our factory. TO AVOID UNNECESSARY DELAYS, PLEASE CALL DIRECT TO OUR TOLL-FREE CUSTOMER HOT LINE.
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the following important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions. 10. Never insert any object into any opening. 11. Do not use breakable containers in or near the hydrotherapy spa. 2.
20. DANGER—Risk of electric shock. Keep all electrical appliances such as radios, telephones, televisions, and lights at least five feet away from the water. physician before using the hydrotherapy spa. Pregnant women should not use the spa if the water temperature is above 100°F; the unborn child could be seriously harmed. This is especially important during the first 90 days of the pregnancy. 21. A wire connector is provided on the electronics pack of the hydrotherapy spa to connect a minimum No.
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa.
Before You Begin Congratulations for selecting the new IMAGE® RENEW 631 hydrotherapy spa. The innovative RENEW 631 allows you to enjoy all the benefits of hydrotherapy in the comfort and privacy of your home. For your benefit, read this manual carefully before using the RENEW 631. If you have additional questions, please call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays).
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your home.
Assembly Before beginning assembly, carefully read the following information and instructions: ASSEMBLY REQUIRES THE FOLLOWING TOOLS (not included): • Place all parts in a cleared area and remove the packing materials from the spa shell. Do not dispose of the packing materials until assembly is completed and the spa is operating. • One (1) phillips screwdriver • You may also need a small amount of soap or water. • During assembly, make sure that all parts are oriented as shown in the drawings.
3. Refer to the drawing on page 6 and locate the heater access opening. 3 Gate Valve Locate the two indicated gate valves inside the heater access opening. Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves (refer to the inset drawing in step 2 on page 8). Make sure that the four indicated collars are tightened. Collar Gate Valve Collar Collar Electronics Pack Refer to step 1.
Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat five adults. The spa holds 295 gallons of water and offers a heating system (80°F to 104°F), a filtration system, and adjustable hydrotherapy jets. Follow the guidelines below to use and maintain the spa for your long-term enjoyment. If the level is too high, add half of one of the “QUICK pHix It DOWN” packets to the water. Let the water circulate through the spa for five minutes. Test the pH level again.
Spa Shell Diagram D D O O A A D C E K E H B F K I A J A P N O G M L A. The eight adjustable push/pull jets allow you to direct their water flow and can be closed and opened with a push or a pull on their nozzles. Water pressure to the other hydrotherapy jets can be increased by closing the adjustable push/pull jets. If no air flows through the jets when the air control is turned counterclockwise, pull the nozzles slightly. I. The temperature probe monitors water temperature. J.
Using the Controls Air Control 1 Air Control 2 Display Invert Button l Jet Button 1 Refer to the diagram above. The function of each control is explained below: Display ll Jet Button 2 Light Button Temperature Buttons Jet Button 1: Turns the spa jets labeled A (at the left) on and off. If the button is pressed once, the jets will run, providing gentle hydrotherapy. If the button is pressed again, the jets will shut off.
Maintenance The hydrotherapy spa is designed to provide years of enjoyment. Please follow the guidelines below to properly maintain your spa. MAINTAINING THE SPA COVER The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover entirely. Use a non-silicone-based vinyl conditioner on the cover after you clean it. This will help protect the cover from sun damage.
WATER CHEMISTRY ATTACHING AND REMOVING THE ACCESS PANEL The hydrotherapy spa comes with a starter chemical pack for maintaining the water in the spa. (See TESTING AND TREATING THE WATER on page 10.) Additional chemicals can be purchased at a pool and spa supply store. To locate the access panels, refer to the drawing on page 6. Turn off the spa power. To remove an access panel, first remove the four indicated screws. Slide the access panel down and then pull the bottom of it away from the spa.
To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE 1. Using the console, adjust the temperature to the lowest setting. 2. Shut off the power to the spa, at the circuit breaker or GFCI. 3. Remove the pump access panel from the spa. 4. Remove the end of the drain hose from the spa. Remove the cap and attach a garden hose to the drain hose. Cap Valve Knob Drain Hose 5. Open the valve by turning the valve knob. The water will begin to drain. 6.
Trouble-shooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set temperature. a. Check to see if the GFCI breaker is tripped or was not turned on.
10. SYMPTOM: THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF 12. SYMPTOM: THE CONSOLE DISPLAYS THE WORDS “COOL” OR “ICE” a. To turn the main jets off, press the pump button once. NOTE: If the actual spa water temperature is below the set temperature, or if the spa is running a filter cycle, the heater pump/motor will not shut off. a. This is a normal function of the spa; no action is necessary.
Part List—Model No. IMHS63100 Key No. Qty. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 1 2 1 1 2 2 32 1 4 1 1 1 4 1 1 1 3 2 1 2 2 2 1 11 4 8 2 Description R0700A Key No. Qty.
Exploded Drawing—Model No.
Ordering Replacement Parts To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be prepared to give the following information when calling: 1. The MODEL NUMBER of the product (IMHS63100) 2. The NAME of the product (IMAGE® RENEW 631 hydrotherapy spa) 3. The SERIAL NUMBER of the product (see the front cover of this manual) 4.