4.3.5.2.To establish an association between SLAVE area and RX equipment
The user must establish an association (i.e. binding) between the SLAVE area and the RX
device to control the device through the SLAVE. Mainstream follows:
A. Connect the RX device to input power supply, power supply lights long;
B. A user switches SLAVE to a specified area;
C. The user presses and immediately loosens the RX device key, RX enters the SLAVE to be
bound state, at this time RX the red indicator light will flash twice;
D. A user presses a SLAVE open or close key;
E. When the binding is successful, the RX operation indicator flashes three times. If the binding
fails, the RX operation indicator lights will go out.
4.3.5.3. To establish SLAVE association with HUB equipment
The user must establish an association (i.e. binding) between the SLAVE and the HUB device
in order to pass the SLAVE address to the HUB device so that the RX device bound to the device
can be controlled. Mainstream follows:
A. A user connected to the HUB equipment power supply, power lights long light;
B. HUB short press button, Hub middle STATUS lights flicker 2 times;
C. SLAVE user switches to any area;
D. A user presses SLAVE open or close key;
E. The middle STATUS lamp of the HUB flashes 2 times if the binding fails; if the binding fails,
the middle STATUS lamp goes out.
4.3.5.4. To establish HUB association with RX equipment
This applies only to cases where only HUB and RX, not SLAVE:
A. First, follow the 4.3.5.1. steps to establish an account association with HUB equipment。
B. HUB press 5 times in a row and Led flash 5 times;
C. Connect the RX device to input power supply, power supply lights long;
D. The user presses and immediately loosens the RX device button RX enters the state to be
bound, when the RX red indicator flashes twice;
E. Mobile phone selection area and click。