Manual

Report No.: C140428Z01-RP1
FCC ID: 2AAHXMXH-BT800 Page 9 of 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
6. FCC PART 15.247 REQUIREMENTS
6.1 20DB BANDWIDTH
None; for reporting purpose only.
MEASUREMENT EQUIPMENT USED
Name of
Equipment
Manufacturer Model Serial Number Last Calibration
Due
Calibration
Spectrum Analyzer Agilent E4446A US44300399 03/01/2014 03/01/2015
Remark: Each piece of equipment is scheduled for calibration once a year.
TEST CONFIGURATION
TEST PROCEDURE
1. Place the EUT on the table and set it in the transmitting mode.
2. Remove the antenna from the EUT, then connect a low loss RF cable from antenna
port to the spectrum analyzer.
3. Set the spectrum analyzer as RBW=30kHz, VBW=100kHz, Span=3MHz, Sweep =
auto.
4. Mark the peak frequency and 20dB (upper and lower) frequency.
5. Repeat until all the test channels are investigated.
TEST RESULTS
No non-compliance noted
EUT
Spectrum
Analyzer