Report No.: C140428Z01-RP1
FCC ID: 2AAHXMXH-BT800
Page 59 / 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
TEST CONFIGURATION
See test photographs attached in Appendix 1 for the actual connections between EUT
and support equipment.
TEST PROCEDURE
1. The EUT was placed on a table, which is 0.8m above ground plane.
2. Maximum procedure was performed on the six highest emissions to ensure EUT
compliance.
3. Repeat above procedures until all frequency measured were complete.
TEST RESULTS
The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range. Significant peaks are then marked as shown on the following data
page, and these signals are then quasi-peaked.
EUT
LISN
EMI receive
r
Reference ground plane
Vert. reference plane
40cm
80cm