Page 58 / 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
6.9 POWERLINE CONDUCTED EMISSIONS
LIMIT
For an intentional radiator which is designed to be connected to the public utility (AC)
power line, the radio frequency voltage that is conducted back onto the AC power line on
any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250
microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz
to 0.50 MHz)
. The limits at specific frequency range is listed as follows:
Limits (dBμV)
Frequency Range (MHz)
Quasi-peak Average
0.15 to 0.50 66 to 56 56 to 46
0.50 to 5 56 46
5 to 30 60 50
Compliance with this provision shall be based on the measurement of the radio
frequency voltage between each power line (LINE and NEUTRAL) and ground at the
power terminals.
MEASUREMENT EQUIPMENT USED
Conducted Emission Test Site
Name of
Equipment
Manufacturer Model Number Serial Number
Last
Calibration
Due
Calibration
EMI TEST RECEIVER ROHDE&SCHWARZ ESCI 100783 03/09/2014 03/08/2015
LISN(EUT) ROHDE&SCHWARZ ENV216 101543-WX 04/20/2014 04/19/2015
LISN EMCO 3825/2 8901-1459 03/09/2014 03/08/2015
Temp. / Humidity Meter VICTOR HTC-1 N/A 03/17/2014 03/17/2015
Test S/W FARAD EZ-EMC/ CCS-3A1-CE
Remark: Each piece of equipment is scheduled for calibration once a year.