Report No.: C140428Z01-RP1
FCC ID:
2AAHXMXH-BT800 Page 46/60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
6.8.2. RADIATED EMISSIONS
LIMIT
1. Except as provided elsewhere in this Subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:
Frequency (MHz) Field Strength (mV/m)
Measurement Distance
(m)
0.009-0.490 2400/F(kHz) 300
0.490-1.705 24000/F(kHz) 30
1.705-30.0 30 30
30-88 100* 3
88-216 150* 3
216-960 200* 3
Above 960 500 3
Note: Except as provided in paragraph (g), fundamental emissions from intentional
radiators operating under this Section shall not be located in the frequency bands
54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within
these frequency bands is permitted under other sections of this Part, e.g., Sections
15.231 and 15.241.
2. In the above emission table, the tighter limit applies at the band edges.
Frequency (Hz)
Field Strength
(μV/m at 3-meter)
Field Strength
(dBμV/m at 3-meter)
30-88 100 40
88-216 150 43.5
216-960 200 46
Above 960 500 54