Manual
Report No.: C140428Z01-RP1
FCC ID: 2AAHXMXH-BT800
Page 32 / 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
6.7 TIME OF OCCUPANCY (DWELL TIME)
LIMIT
According to ยง15.247(a)(1)(iii), Frequency hopping systems operating in the
2400MHz-2483.5 MHz bands. The average time of occupancy on any channels shall not
greater than 0.4 s within a period 0.4 s multiplied by the number of hopping channels
employed.
MEASUREMENT EQUIPMENT USED
Name of
Equipment
Manufacturer Model Serial Number
Last
Calibration
Due
Calibration
Spectrum Analyzer Agilent E4446A US44300399 03/01/2014 03/01/2015
Remark: Each piece of equipment is scheduled for calibration once a year.
Test Configuration
TEST PROCEDURE
1. Place the EUT on the table and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the
antenna port to the spectrum analyzer.
3. Set center frequency of spectrum analyzer = operating frequency.
4. Set the spectrum analyzer as RBW, VBW=1MHz, Span = 0Hz, Sweep = auto.
5. Repeat above procedures until all frequency measured were complete.
EUT
Spectrum
Analyzer