Manual
Report No.: C140428Z01-RP1
FCC ID: 2AAHXMXH-BT800
Page 29 / 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
6.6 NUMBER OF HOPPING FREQUENCY
LIMIT
According to ยง15.247(a)(1)(ii), Frequency hopping systems operating in the
2400MHz-2483.5 MHz bands shall use at least 15 hopping frequencies.
MEASUREMENT EQUIPMENT USED
Name of
Equipment
Manufacturer Model Serial Number
Last
Calibration
Due
Calibration
Spectrum Analyzer Agilent E4446A US44300399 03/01/2014 03/01/2015
Remark: Each piece of equipment is scheduled for calibration once a year.
Test Configuration
TEST PROCEDURE
1. Place the EUT on the table and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the
antenna port to the spectrum analyzer.
3. Set spectrum analyzer Start=2400MHz, Stop =2441.5MHz, Sweep = 1ms and
Start=2441.5MHz, Stop = 2483.5MHz, Sweep = 1ms.
4. Set the spectrum analyzer as RBW, VBW=300kHz,
5. Max hold, view and count how many channel in the band.
TEST RESULTS
No non-compliance noted
Test Data
Result (No. of CH) Limit (No. of CH) Result
79 >15 PASS
EUT
Spectrum
Analyzer