FCC ID: 2AAHXMXH-BT800 Page 17 of 60
This report shall not be reproduced except in full, without the written approval of Compliance Certification Services.
TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above the ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of
maximum emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to
find out the highest emission.
4. Set the spectrum analyzer in the following setting in order to capture the lower and
upper band-edges of the emission:
(a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
(b) AVERAGE: RBW=1MHz / VBW=2.4kHz / Sweep=AUTO
5. Repeat the procedures until all the PEAK and AVERAGE versus POLARIZATION
are measured.
TEST RESULTS
Refer to attach spectrum analyzer data chart.