User's Manual

TM70Pi V3.2 (11/03) 120021.pdf. 92
IKUSI reserves the right to change this information without prior notice
LIMIT VALUES:
Set the limits of the analogue output (+ Smin, Smin, smax + smax and Scero) NOTE: These actions
involve movement of the manoeuvre to adjust!
The adjustment of MAX and MIN values is performed with the manoeuvre moved for know which
output and which semiaxis is going to be adjusted.
As you are pressing UP/DOWN keys, value will be updated on the screen.
ZERO value of the output will be adjusted with the manoeuvre in the neutral position.
The LCD will guide at all times to report that the five possible parameters are adjusted depending on
the position of the paddles.
ZERO RELE ON: By entering this submenu is permanently activated the output of the expansion in
the absence of a order. This can be used to identify potential errors that cause unwanted movements.
POLARITY INV:
It allows the reverse polarity of outlets, such as:
CURVE TYPE:
Tour types of curve available:
Type 0: Linear response.
Type 1, 2 y 3: Exponential responses.
RAMPS:
The acceleration and/or deceleration ramp speed is defined for each semiaxis by a parameter that can take
a value between 0 and 15, default 0. Each of these values is a ramp time defined in seconds by the following
table:
0 without ramp 4 0,4 s 8 1,0 s 12 2,0 s
1 0,1 s 5 0,5 s 9 1,2 s 13 2,5 s
2 0,2 s 6 0,6 s 10 1,5 s 14 3,5 s
3 0,3 s 7 0,8 s 11 1,7 s 15 5,0 s
These values are modified by EEPROM recorder.