User's Manual

TM70Pi V3.2 (11/03) 120021.pdf. 12
IKUSI reserves the right to change this information without prior notice.
7.3 - TROUBLESHOOTING
The transmitter and receiver have status monitoring LED’s, which help to identify irregularities.
The most common signals are contained in the tables below:
TRANSMITTER
LED MEANS
Solid green Transmitter transmitting normally. OPERATION mode.
Green pulses. Transmitter ready for start-up. STAND BY mode.
Red slow flashing Battery level low
Red fast flashing Probably, EEPROM module is not plugged in.
Red double flashing Transmitter cannot start up because a manoeuvre command is
present.
Solid red Transmitter failure
RECEIVER
In OPERATION mode the 5 LED’s must be lit as has been previously described in section 4.3
Starting. If this is so, press the transmitter manoeuvre buttons and observe the response of the
output relays. If the response is normal, the problem is not related to the remote control
equipment and the installation must be checked. If any of the relays is not activated, the
problem is associated with the remote control equipment. If this happens, observe the
appearance of the LED’s:
LED LIT FLASHING OFF
POWER Power Supply OK -- Power Supply not OK
HARDOK Board OK
Slow: fault in the board
Fast: error in EEPROM
Fault in the board
SIGNAL RF signal OK RF signal detection in
SCANNING mode
The receiver is not receiving
RF signals
DATA -- Is receiving the correct data
from a TM70
Signal received is not
correct
ID -- ID Code OK ID not recognised
ORDER Any digital
manoeuvre ON
-- No digital manoeuvre ON
RELAY STOP relays ON -- STOP relays OFF