User's Manual

TM70Pi V3.2 (11/03) 120021.pdf. 8
IKUSI reserves the right to change this information without prior notice.
5.3 - STARTING UP
Proceed with caution; the equipment may not be connected correctly which may
lead to unforeseeable movements on starting-up.
Once the receiver has been connected, disconnect the power supply to the motors, (for example, by
removing the fuses) and power on the receiver. First of all the LEDs will light on an instant to test that all are
all right, after this the receiver will enter into a ‘SCANNING mode and the following LED’s will be lit in the
receiver;
POWER (1): ON, indicates that the power supply is correct.
HARDOK (2): ON, indicates the absence of faults on the boards.
SIGNAL (3): OFF, in the case of the channels being signal free. Blinks ON when
there is a RF signal on the channels.
DATA (4): OFF, when there is not another TM70 system active in the area.
Blinks ON in the opposite case.
ID (5): OFF
CAN_RUN (6): ON, Indicates that CAN communications with expansion boards are
OK.
CAN_ERR (7): OFF
ORDER (8): OFF
RELAY (9): OFF
Figure 7. Signalling LEDs in the receiver.
1.-Label for crane
identification.
2.-LED.
3.-Command elements.
4.-Contact key.
5.-Start button.
6.-STOP button.
7.-Option: LA70 Range
Limitation.
8.-Optional: LCD70 Display +
LA70 (able to be activated by
EEPROM).
Figure 8. Command and signalling elements in the transmitter
1
2
3
4
5
7
8
6