Connect the power supply and the receiver outputs on the corresponding relay board plug-in terminals. Do
this following the outputs diagram, which is supplied with the set. This diagram indicates the correspondence
between the transmitter commands and the receiver outputs.
The STOP relays KSTOP1 y KSTOP2 are in series and must be connected to the main
contactor coil circuit.
The K2/START is activated once the start-up command is held down.
The K1/SAFETY relay is a safety relay, which is activated when certain commands predefined
as “active” on configuration of the set, (i.e. commands which give rise to manoeuvres), are
activated.
.
Figure 6. Receiver’s electronic card
Remember to connect the ground cable.
Only use fireproof cables for connections.
Select the appropriate voltage on the receiver, (230, 115 or 48 Vac – 12 or 24 Vcc)