Connect the power supply and the receiver outputs on the corresponding relay board plug-in terminals. Do
this following the outputs diagram, which is supplied with the set. This diagram indicates the correspondence
between the transmitter commands and the receiver outputs.
The STOP relays KSTOP1 y KSTOP2 are in series and must be connected to the main
contactor coil circuit.
The K2/START is activated once the start-up command is held down.
The K1/SAFETY relay is a safety relay, which is activated when certain commands predefined
as “active” on configuration of the set, (i.e. commands which give rise to manoeuvres), are
activated.
.
Figure 6. Receiver’s electronic card
Remember to connect the ground cable.
Only use fireproof cables for connections.
Select the appropriate voltage on the receiver, (230, 115 or 48 Vac 12 or 24 Vcc)