User's Manual

TM70Bi V3.2 (11/02) 1121174 L0.pdf 27
IKUSI reserves the right to change this information without prior notice.
9.5 - SIGNALLING
The receiver is furnished with two signalling LEDs, controlled according to CiA DR-303-3
recommendation:
CAN-RUN (green): indicates the system state inside the CANopen machine state:
- Blinking every 200 ms. In preoperational state.
- Solid green permanently in operational state.
- One blink every second in stop state.
CAN-ERR (red): indicates error if switched on; in normal conditions it must be switched off.
9.6 - TM70 CAN RECEIVERS
Ref. 3302750 (7503 70GR401 RX R70CANC3 433)
Ref. 3302751 (7504 70GR903 RX R70CANC3 915)
R70CANC3 RECEIVER
Specifications
Available frecuencies (ISM bands) 915MHz (FCC certified)
433MHz
Power supply / Maximum consumption 9-35v DC / 5W maximum
Inputs / Outputs interface CAN:Standard CAN Open protocol 401 (CIA DS401)
Ingress protection IP67 / NEMA-6
Antenna External: NEARSON S325TR-015 or equivalent
Working frequency selection Automatic: LBT (listen before talking)
Weight 430 gr.
Dimensions Long = 151mm / Width = 129mm (160mm with PG) /
Height = 61mm
EEPROM Extractable EP70 module
Signaling MultiLED:
7 external LEDS (6 green + 1 bicoloured)
2 internal LEDS (CAN status: 1 red + 1 green)
Connexions Fast PLUG-IN plugs and 2 x M16 cable glands
1) Power supply cable gland: M16 / IP67
2) Inputs / Outputs interface cable gland: M16 / IP67
STOP function Cat. 3 EN-954-1 / 2 STOP relays: 250V / 6A maximum
STOP response time = 50 miliseconds
CAN BUS termination (120 Ohm) ON / OFF jumper (internal)
Passive STOP time Programmable: 0,5 to 2 seconds (máx)
Input protection PTC / 0,3A fuse
Output protections (STOP) VDR in contacts
Operating mode temperatura range -20ºC / +70ºC (-4ºF / 158ºF)
Storage temperatura (24h) -25ºC / +75ºC (-13ºF / 167ºF)
Storage temperature –long periods- -25ºC / +55ºC (-13ºF / 131ºF)
TM70 range supported transmitters T70/1/2; T70/3/4; T70/5/6; T70/7/8
Available complete systems Ref. 3302XXX Equipo comp. TM70/X.CAN-C1-915