Pizza prep tables Sandwich/Salad Units Under-counter Refrigerators and Freezers Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment. Notify carrier of damage! Inspect all components immediately.
Service and Installation Manual COMMERCIAL REFRIGERATOR SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. Our product instructions will be uploaded on our company official website. This is the Safety Alert Symbol. This symbol alerts you to potential hazards that can kill or injure you and others.
Service and Installation Manual The key for appliance electric box should be safe kept by qualified persons in order to avoid a hazard WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. WARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. WARNING: Do not damage the refrigerant circuit.
Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENT ............................................................................................ 4 SPECIFICATIONS .......................................................................................................................................... 5 INSTALLATION ..................................................................................................................................................... 6 OPERATION ...........
Service and Installation Manual SPECIFICATION SANDWICH/SALAD UNITS FULL STORAGE PAN LOAD CAPACITY 1/6 MODEL# V/Hz/Ph AMPS Cu-ft Size HP 5.2 3.0 ISP29 115/60/1 8 1/3 8.8 4.3 ISP48 115/60/1 12 1/2 11.5 4.3 ISP61 115/60/1 16 1/2 13.1 4.3 ISP72 115/60/1 18 1/2 SANDWICH/SALAD UNITS MEGA TOP FULL STORAGE LOAD CAPACITY MODEL# V/Hz/Ph AMPS Cu-ft 5.2 ISP29M 115/60/1 3.0 8.8 ISP48M 115/60/1 4.3 4.3 11.5 ISP61M 115/60/1 13.1 ISP72M 115/60/1 4.
Service and Installation Manual INSTALLATION Location Units represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded unit can weigh as much as 1500 pounds. Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out.
Service and Installation Manual OPERATION Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet. CAUTION Refrigerated cabinets Temperature range for the internal cabinets is 33°F to 40°F for all food prep units, undercounter and worktop refrigerators, and -7°F to -3°F for undercounter and worktop freezers. The rail’s temperature range for all prep units is 33°F to 41°F. Food Prep units should operate with pans in place.
Service and Installation Manual 1.1 Function of LEDS 2. MAIN FUNCTIONS 2.1 HOW TO SEE THE SETPOINT 1. Push and immediately release the SET key: the display will show the set point value. 2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again. 2.2 HOW TO CHANGE THE SETPOINT 1. Push the SET key for more than 2 seconds to change the set point value. 2. The value of the set point will be displayed and the LED starts blinking. 3.
Service and Installation Manual MAINTENANCE DANGER The power switch must be turned OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the "grain" of the stainless steel to avoid marring the finish.
Service and Installation Manual MAINTENANCE Cleaning solutions need to be alkaline based or non-chloride based. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used, be sure to rinse and dry thoroughly. Routine cleaning of stainless steel can be done with soap and water.
Service and Installation Manual WIRING DIAGRAM MODEL: IUC27 N L PLUG DOOR SWITCH OVERLOAD PROTECTOR CONDENSER FAN THERMOSTAT DISPLAY ROOM EVAP SENSOR COMPRESSOR FAN POWER EVAP FAN STARTING CAPACITOR CURRENT RELAY 11
Service and Installation Manual WIRING DIAGRAM MODEL: IUC48/IUC60 N L PLUG OVERLOAD PROTECTOR DOOR SWITCH CONDENSER FAN FAN POWER THERMOSTAT DISPLAY ROOM EVAP STARTING CAPACITOR EVAP FAN COMPRESSOR CURRENT RELAY SENSOR MODEL: IUC72 N L PLUG OVERLOAD PROTECTOR THERMOSTAT DISPLAY CONDENSER FAN DOOR SWITCH ROOM FAN POWER EVAP SENSOR EVAP FAN 12 COMPRESSOR CURRENT RELAY STARTING CAPACITOR
Service and Installation Manual WIRING DIAGRAM MODEL: IPP47 THERMOSTAT DISPLAY N L PLUG DOOR FRAME HEATER CIRCUITALION FAN MOTOR EVAP ROOM OVERLOAD PROTECTOR SENSOR CONDENSER FAN MOTOR COMPRESSOR t ℃ PTC STARTER MODEL: IPP71 THERMOSTAT DISPLAY N L OVERLOAD PROTECTOR CIRCUITALION FAN MOTOR M SENSOR MIDDLE FRAME HEATER EVAP ROOM DOOR FRAME HEATER PLUG M CONDENSER FAN MOTOR STARTING CAPACITOR COMPRESSOR CURRENT RELAY 13
Service and Installation Manual WIRING DIAGRAM MODEL:IPP94 THERMOSTAT DISPLAY CIRCUITALION FAN MOTOR M SENSOR MIDDLE FRAME HEATER EVAP ROOM DOOR FRAME HEATER PLUG MIDDLE FRAME HEATER N L OVERLOAD PROTECTOR M CONDENSER FAN MOTOR COMPRESSOR CURRENT RELAY STARTING CAPACITOR MODEL: ISP29/ ISP29M THERMOSTAT DISPLAY N L OVERLOAD PROTECTOR EVAP ROOM CIRCUITALION FAN MOTOR SENSOR DOOR FRAME HEATER PLUG CONDENSER FAN MOTOR COMPRESSOR t ℃ PTC STARTER 14
Service and Installation Manual WIRING DIAGRAM MODEL: ISP48/ ISP61/ ISP48M/ ISP61M THERMOSTAT DISPLAY N L OVERLOAD PROTECTOR DOOR FRAME HEATER CIRCUITALION FAN MOTOR MIDDLE FRAME HEATER PLUG EVAP ROOM SENSOR CONDENSER FAN MOTOR COMPRESSOR t ℃ PTC STARTER MODEL: ISP72/ ISP72M THERMOSTAT DISPLAY EVAP ROOM SENSOR MIDDLE FRAME HEATER CIRCUITALION FAN MOTOR DOOR FRAME HEATER PLUG MIDDLE FRAME HEATER N L OVERLOAD PROTECTOR CONDENSER FAN MOTOR COMPRESSOR t ℃ PTC STARTER 15
Service and Installation Manual WIRING DIAGRAM MODEL: IUC28F N L PLUG THERMAL CUT-OFF DOOR SWITCH OVERLOAD PROTECTOR COMPRESSOR CONDENSER FAN FAN POWER THERMOSTAT DISPLAY EVAP FAN ROOM STARTING CAPACITOR EVAP CURRENT RELAY SENSOR MODEL: IUC48F IUC61F N L PLUG DOOR SWITCH FAN POWER THERMOSTAT DISPLAY ROOM EVAP SENSOR 16 EVAP FAN MIDDLE FRAME HEATER THERMAL CUT-OFF OVERLOAD PROTECTOR CONDENSER FAN STARTING CAPACITOR COMPRESSOR CURRENT RELAY
Service and Installation Manual WIRING DIAGRAM MODEL:IUC72F N L FAN POWER THERMOSTAT DISPLAY ROOM EVAP EVAP FAN MIDDLE FRAME HEATER DOOR SWITCH MIDDLE FRAME HEATER THERMAL CUT-OFF PLUG OVERLOAD PROTECTOR CONDENSER FAN COMPRESSOR STARTING CURRENT CAPACITOR RELAY SENSOR 17
Service and Installation Manual WIRING DIAGRAM MODEL: IUC28 18
Service and Installation Manual WIRING DIAGRAM MODEL: IUC48/IUC61 19
Service and Installation Manual WIRING DIAGRAM MODEL: IUC72 20
Service and Installation Manual WIRING DIAGRAM MODEL: ISP29 / ISP29M 21
Service and Installation Manual WIRING DIAGRAM MODEL: ISP48 / ISP61 / ISP48M / ISP61M 22
Service and Installation Manual WIRING DIAGRAM MODEL: ISP72 / ISP72M 23
Service and Installation Manual WIRING DIAGRAM MODEL: IPP47 24
Service and Installation Manual WIRING DIAGRAM MODEL: IPP71 25
Service and Installation Manual WIRING DIAGRAM MODEL: IPP94 26
Service and Installation Manual WIRING DIAGRAM MODEL: IUC28F 27
Service and Installation Manual WIRING DIAGRAM MODEL: IUC28F 28
Service and Installation Manual WIRING DIAGRAM MODEL:IUC48F/IUC61F 29
MODEL: IUC72F WIRING DIAGRAM
Service and Installation Manual IKON WARRANTY Two Year Parts & Labor Warranty MVP Group (IKON) warrants, to the original purchaser, all of its new equipment to be free from defects in material and workmanship, under normal use and maintenance service, for a period of two (2) years from the date of original purchase or 15 months after shipment date from the manufacturer, whichever occurs first.