User Manual

Table Of Contents
45
FAULT CAUSE TROUBLESHOOTING
E:18 or indicator for
water supply lights up.
Filter in the water sup-
ply is blocked.
1. Switch off the appliance.
2. Pull out the mains plug.
3. Turn off the water tap.
4. Unscrew the water connec-
tion.
5. Remove the filter from the
supply hose
6. Clean the filter.
7. Re-insert the filter in the sup-
ply hose.
8. Screw the water connection
back on.
9. Check the water connection
for leaks.
10. Restore the power supply.
11. Switch the appliance on.
E:22 lights up. Filters are soiled or
blocked.
Clean the filters.
→"Cleaning filters", Page41
E:24 lights up. Water is
not drained.
Wastewater hose is
blocked or kinked.
1. Reposition the wastewater
hose without kinks.
2. Remove residues.
Siphon connection is
still sealed.
Check the connection to the
siphon and open if neces-
sary.
Cover of the wastewa-
ter pump is loose.
Secure the cover of the
"Wastewater pump "
→Page58 so it clicks into
position.
E:25 lights up. Wastewater pump is
blocked.
Clean the wastewater pump.
→"Clean wastewater pump",
Page58