9ENGLISH
3. After cleaning the grease lter, remount in
reverse order ensuring the entire extraction
surface is covered.
Charcoalltermaintenance(ifthehoodis
installedinrecirculationinstallation)
1. Pull out the plug or disconnect the power
supply.
2. Remove the grease lter
3. If the carbon lters are already tted (two
lters that cover the protective grilles for the
motor impeller) and have to be replaced,
turn the central handle anti-clockwise to
unlock them.
4. Open the two lter shells
5. Pull out the two circular mats
6. Proceed in reverse order to t the new
lters.
7. Ret the grease lters.
Unlike traditional charcoal lters, this
charcoal lter can be washed and
reactivated.
Care and cleaning long life Charcoal lter
• The anti-odour lter shall be washed and
regenerated every 3-4 months (or more
frequently if the hood is subject to intensive
use), up to a Max. of 8 regeneration cycles
(in case of particularly intensive use it is
recommended that you do not exceed 5
cycles).
Regeneration procedure:
• Wash in the dishwasher at a MAX
temperature of 70° or hand wash in hot
water without using abrasive sponges (do
not use detergents!)
• Dry in the oven at a MAX temperature of
70° for 2 hours or dry at room temperature,
standing the lter in a vertical position to
facilitate drainage.
Lampmaintenance
1. Disconnect the hood from the power
supply.
2. Open the extractor grille or remove the
self-supporting grease lter.
3. Replace the damaged lamp. Use E14 3W
max LED lamps only.
4. Ret the extractor grille or grease lter.
IMPORTANT: make sure you don’t touch the
lamp with your bare hands.
Lamp Power
(W)
Socket Voltage
(V)
LCL ILCOSDCode
3 E14 230 55
DRGSB/C/UB-3/27/
1B-230-E14-55