Installation guide
For non-vented (recirculating) installations, you will also
need:
• Charcoal Filter Kit Part Number 4396848 for non-vented
(recirculating) installations only. See "Assistance or Service"
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
• Hood canopy assembly with ventilator and light bulbs
installed
• Deflector for non-vented (recirculating) installations
• Vent transition with back draft dampers installed
• Filter(s) - depending on model and size
• 2 mounting hooks
• Vent cover support bracket
• Mounting template
• 2-piece vent cover
• Rubber tape
• 2 - 2.9 x 6.5 mm screws
• 2 - 3.5 x 6.5 mm screws
• 2 - 3.5 x 9.5 mm screws
• 2 - 6.0 x 70.0 mm screws
• 6 - 5.0 x 35.0 mm mounting screws
• 2 - 10.0 x 60.0 mm drywall anchors
• Allen wrench for Torx_t head screws
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent
hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in "Prepare Location" section.
Charcoal Filter Kit Part Number 4396848 is available from your
dealer or an authorized parts distributor.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local
codes.
Product Dimensions
Installation Dimensions
61/2"
(16.5 cm)
'%, _r-..........._ 2" (5.1 cm) rain.
"_ -=.-_---:;:---:-_--_.-.. 9" (22.9 cm) rain*
+
Side
cabinet
Side
cabinet
*For non-vented (recirculating) installations
I"®TORX is a registered trademark of Acument Intellectual Properties, LLC.