Manual
9
4. Drill
3
/
8
" (9.5 mm) holes for wall anchors and insert anchors
flush with the wall.
5. Attach vent cover support bracket to wall.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See the “Venting Requirements” section.
2. Determine the required height for the home power supply
cable and drill a 1¼" (3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough ½" conduit and wires
from the fused disconnect (or circuit breaker) box to make
the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
Install Range Hood
Non-Vented (recirculating) Installation
NOTE: Remove protective film from range hood and metal filters.
1. Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
2. Remove the grease filter. See the “Range Hood Care”
section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws with flat
washers and tighten.
Connect Vent System
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that backdraft dampers work properly.
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the 2 extensions with
2 - 3.5 x 6.5 mm screws provided.
2. Assemble the air deflector with the duct cover bracket with
4 - 3.5 x 6.5 mm screws provided.
3. Measure from the bottom of the air deflector to the bottom
of the hood outlet.
A
B
C
D
E
A. 8 x 40 mm drywall anchors
B. Centerline on wall
C. Vent cover support bracket
D. 5 x 45 mm screws
E. Centerline of bracket
A
B
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws with flat washers
A
A
A. 3.5 x 6.5 mm screws
A. Vent cover bracket
B. 3.5 x 6.5 mm screws
C. Air deflector
A
B
C
A
C
X
D
B
E
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet