Manual
10
4. Cut the duct to the measured size (X).
5. Remove the air deflector.
6. Slide the duct onto the bottom of the air deflector.
7. Place the assembled air deflector and duct over the exhaust
outlet from the hood.
8. Reassemble the air deflector to the duct cover bracket with
2 assembly screws.
9. Seal connections with vent clamps.
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved
1
/
2
" strain relief.
4. Run home power supply wiring through
1
/
2
" strain relief into
terminal box.
5. Use UL listed wire connectors and connect white wires
(D) together.
6. Use UL listed wire connectors and connect black wires
(E) together.
7. Connect green (or bare) ground wire from home power
supply to the 2 yellow-green ground wires (F) in terminal box
using UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
C
A. Terminal box
B. Knockout
C. Terminal box cover
A
B
C
D
E
F
G
A. Home power supply
B. UL listed or CSA
approved strain relief
C. UL listed wire connectors
D. White wires
E. Black wires
F. Green (or bare) and
yellow-green wires
G. Terminal box
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.