Manual

58
032010
Solvent Formula Pressure for
boiling point
40 °C in mbar
Acetic acid C
2
H
4
O
2
44
Acetone C
3
H
6
O 556
Acetonitrile C2H3N 226
N-Amylalcohol, C
5
H
12
O 11
n-Pentanol
n-Butanol C
4
H
10
25
tert. Butanol, C
4
H
10
O 130
2-Methyl-2-Propanol
Butylacetate C
6
H
12
O
2
39
Chlorobenzene C
6
H
5
CI 36
Chloroform CHCI
3
474
Cyclohexane C
6
H
12
235
Dichloromethane, CH
2
CI
2
atm.press.
Methylenechloride
Diethylether C
4
H
10
O atm.press.
1,2,-Dichloroethylene (trans) C
2
H
2
CI
2
751
Diisopropylether C
6
H
14
O 375
Dioxane C
4
H
8
O
2
107
Dimethylformamide (DMF) C
3
H
7
NO 11
Ethanol C
2
H
6
O 175
Ethylacetate C
4
H
8
O
2
240
Ethylmethylketone C
4
H
8
O 243
Heptane C
7
H
16
120
Hexane C
6
H
14
335
Isopropylalcohol C
3
H
8
O 137
Isoamylalcohol, C
5
H
12
O 14
3-Methyl-1-Butanol
Methanol CH
4
O 337
Pentane C
5
H
12
atm.press.
n-Propylalcohol C
3
H
8
O 67
Pentachloroethane C
2
HCI
5
13
1,1,2,2,-Tetrachloroethane C
2
H
2
CI
4
35
1,1,1,-Trichloroethane C
2
H
3
CI
3
300
Tetrachloroethylene C
2
CI
4
53
Tetrachloromethane CCI
4
271
Tetrahydrofurane (THF) C
4
H
8
O 357
Toluene C
7
H
8
77
Trichloroethylene C
2
HCI
3
183
Water H
2
O 72
Xylene C
8
H
10
25
Dimensions of visible display area (W x H) mm 70 x 52
Display TFT-Display
Multiple languages yes
Right and left movement/ interval operation yes
Smooth start yes
Lift automatic
Lifting speed mm/s 50
Stroke mm 140
Setting of lower end stop 60 mm, contactless
Head angle adjustable 0° - 45°
Timer 1-199 minutes
Interval 1-60 sec
Integrated vacuum controller yes
Measurement range mbar (hPa) 1050 - 1
Adjustment range mbar (hPa) 1050 - 1
Measurement accuracy mbar +
2 (+ 1 Digit) if calibritation is done at a constant temperature
Adjustment accuracy mbar adjustable hysteresis
Measurement range of differential temperature K6
Offset balancing range K+
0,5
Interface
USB, RS 232
Ramp programming
yes
Distillation processes programmable yes
Remote control
with accessory labworldsoft
®
Cooling surface (Standard condenser RV 10.1,10.10,10.2,10.20)
cm
2
1200
Minimum cooling water flow rate l/h 30
Maximum cooling water flow rate l/h 100
Cooling water pressure bar 0,5
Cooling water temperature range °C 18 - 22, constantly
Fuse 2 x T1,6A 250V 5x20
Perm. On- time % 100
Perm. ambient temperature °C 5-40
Perm. humidity % 80
Protection acc. to DIN EN 60529 IP 20
Protection class I
Overvoltage category II
Contamination level 2
Weight (no glassware; no heating bath)
kg 18,6
Dimensions
(
W x D x H
)
mm 500 x 440 x 430
Operation at a terrestrial altitude m max. 2000
Subject to technical changes!
Solvent table (excerpt)
Warranty
In accordance with IKA warranty conditions, the warranty period is
24 months. For claims under the warranty please contact your local
dealer. You may also send the machine direct to our factory, enclo-
sing the delivery invoice and giving reasons for the claim. You will
be liable for freight costs.
The warranty does not cover worn out parts, nor does it apply to
faults resulting from improper use, insufficient care or maintenance
not carried out in accordance with the instructions in this operating
manual.