Troubleshooting
I have connected iRig Mic HD-A to my Android device, but it is not recognized and none of my audio
apps work with it.
Remember to always connect the OTG cable to the iRig Mic HD-A before connecting it to the Android device.
Sound is distorted.
Check that the input level on iRig Mic HD-A has been set properly. If the red LED is lighting when you talk or
sing decrease the input level as described in this guide.
The iRig Mic HD-A status LED is always dark blue and I don’t get any sound.
In order for iRig Mic HD-A to turn on, an audio app must first be launched on your Android device or PC.
Android: Be sure you are using an app that use USB (OTG) audio input.
PC: Be sure you have set “iRig Mic HD-A” as the audio input device on the audio app you are using.
Specifications
Microphone Type: condenser, electret
Polar Pattern: cardioid
Interface Type: USB digital microphone with a built-in low-noise, high-definition preamp.
Frequency Response: 40 Hz - 18 kHz, -3dB
Maximum Sound Pressure: 134 dB
Distortion: 3% THD at 134 dB, 1 kHz
Windscreen: built-in
Sensitivity: adjustable over a 40 dB range
Built-in low profile gain control
Built-in multicolor LED for status and audio level indication
Connector Type: standard Micro-USB
Power and Connection: works with Android and PC computer
Size: 185mm/7.28” x 48mm/1.89”
Cables lenght: 1.5m/59”