7.2 Main menu
Press [MODE] to activate the main menu. Use [UP] or [DOWN] to select a submenu.
When the display shows the desired submenu press [ENTER] to open it up. To close
the main menu, press [MODE]. The stored values are displayed in white in the display.
Changed values are displayed in red until they are conrmed with [ENTER].
All previously made settings are retained even when you disconnect the device from
the power grid. To restart with default values, use the function ‘Factory Reset’ .
The following table shows the setting options.
Main menu Menu level 2 Menu level 3 Menu level 4
Meaning
‘DMX Address’ ‘Set DMX address’ 001…512 Setting the DMX address
‘MODE’ ‘DMX Signal Select’ Selection of the DMX transmission type
‘DMX’ DMX via cable
‘Wireless DMX’ DMX via radio transmission
‘DMX Mode’ Selecting a DMX mode
‘DMX 2Ch’ 2-channel DMX mode
‘DMX 4Ch’ 4-channel DMX mode
‘DMX 12Ch’ 12-channel DMX mode
‘DMX 29Ch’ 29-channel DMX mode
‘DMX 45Ch’ 45-channel DMX mode
‘Slave’ ‘Slave’ Operating mode ‘Slave’
‘Fading’ Fade and stroboscope eects
‘Auto Fading’ 0…255 Automatic Fade eect
‘Strobe’ 0…255 Strobe eect
‘Auto’ ‘Strobe Program’ Stroboscope programme
0…5 No function
6…13 Stroboscope pro‐
gramme 1
14…21 Stroboscope pro‐
gramme 2
22…29 Stroboscope pro‐
gramme 3
30…37 Stroboscope pro‐
gramme 4
38…45 Stroboscope pro‐
gramme 5
Operating
16
Xo8 LED Fx Strobe IP65 800W
stroboscope