Symptom Remedy
The unit does not work, no light,
the display is dark
Check the mains connection and the main fuse.
Apparently no function despite
proper power supply
Check whether the device is in DMX mode. If so, check
the unit in another mode.
No response to the DMX con‐
troller
1. Check the DMX connectors and cables for proper con‐
nection.
2. If the unit is in DMX mode with a DMX controller con‐
nected and turned on, the display shows ‘Dmx In’ . If it
doesn't, no valid DMX signal is received. Check whether
the DMX controller is switched on. Check the DMX con‐
nectors and cables for proper connection.
3. If the display shows ‘Dmx In’ but there is still no
response, check the address settings and the DMX
polarity.
4. Try using another DMX controller.
5. Check whether the DMX cables run near or parallel to
high-voltage cables that may cause damage or interfer‐
ence to a DMX interface circuit.
If the procedures recommended above do not succeed, please contact our Service Center. You
can nd the contact information at www.thomann.de.