User manual

1. Press [MENU] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ .
Conrm with [ENTER].
2. Press [UP] or [DOWN] repeatedly until the display shows ‘Dimmer Curve’ . Conrm with
[ENTER].
3. Use [UP] or [DOWN] to select the desired dimmer curve.
The following sub menus are available:
Menu level 3 Function
‘Linear’ without fade time: Rise time 0 ms, fall time 0 ms
Fade time 1 s: Rise time 0 ms, fall time 0 ms
‘Stage’ without fade time: Rise time 780 ms, fall time 1100 ms
Fade time 1 s: Rise time 1540 ms, fall time 1660 ms
‘TV’ without fade time: Rise time 1180 ms, fall time 1520 ms
Fade time 1 s: Rise time 1860 ms, fall time 1940 ms
‘Architectural’ without fade time: Rise time 1380 ms, fall time 1730 ms
Setting the dimmer curve
DIMMER
100%
50%
10%
0%
0 Sec Rise Time Down Time
Time (ms)
0
255
no Fade Time
0
255
1 sec Fade Time
Operating
2bright Pint TW200 IP
35
LED PAR