User manual

1. Press [ENTER] and then [UP] or [DOWN] repeatedly until the display shows ‘Settings’ .
Conrm with [ENTER].
2. Press [UP] or [DOWN] repeatedly until the display shows ‘DMX Fail’ . Conrm with
[ENTER].
3. Use [UP] or [DOWN] to select either ‘Hold’ , ‘Blackout’ or ‘Emergency Light’ to make the
setting to be used when the DMX controller fails.
4. Press [ENTER] to accept the selection.
Display Meaning
‘Hold’ Last DMX value is being held.
‘Blackout’ Spotlight turns o.
‘Emergency Light’ Emergency light is turned on.
Setting the behaviour on DMX
control failure
Operating
2bright Par 18 IP
37
LED Spotlight