Datasheet

Range
0...2 (Through-beam sensor)Sensing range [m]
Excess gain graphs
x: distance in [mm]
y: excess gain factor
Environment
-25...60Ambient temperature [°C]
IP 65Protection
Tests / approvals
EN 60947-5-2EMC
806MTTF [Years]
Mechanical data
modified PPEHousing materials
0.065Weight [kg]
Displays / operating elements
yellowOutput status indication LED
greenOperation LED
redUnsafe zone LED
4 x greenExcess gain LED
Electrical connection
M12 connectorConnection
Wiring
2 : function check
Remarks
Remarks
When through-beam fibre optics are connected light-on mode means
the output function "NC" and when diffuse reflection fibre optics are
connected the output function "NO".
When through-beam fibre optics are connected dark-on mode means
the output function "NO" and when diffuse reflection fibre optics are
connected the output function "NC"
cULus - Class 2 source required
ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB OBF500 04.11.2009