Datasheet
1800200...9999nSP2
2200200...9999FSP2
00...9999ASP
99990...9999AEP
501...50rATE [Hz]
00...0,1...5dS1
00...0,1...5dr1
00...0,1...5dS2
00...0,1...5dr2
00...0,1...5dAP
d3d1..3; rd1...3; OFFdIS
Reproduzierbarkeit / Genauigkeit
Messfrequenz 50 Hz
GenauigkeitReproduzierbarkeit der Messwerte
grau (18 % Remission)weiß (90 % Remission)grau (18 % Remission)weiß (90 % Remission)
± 18,0 mm± 15,0 mm± 7,5 mm± 5,0 mm200...1000 mm
± 20,0 mm± 15,0 mm± 10,0 mm± 5,5 mm1000...2000 mm
± 32,0 mm± 25,0 mm± 22,5 mm± 17,5 mm2000...4000 mm
± 50,0 mm± 35,0 mm± 40,0 mm± 27,5 mm4000...6000 mm
--± 70,0 mm--± 60,0 mm6000...10000 mm
Reproduzierbarkeit / Genauigkeit
Messfrequenz 1 Hz
GenauigkeitReproduzierbarkeit der Messwerte
grau (18 % Remission)weiß (90 % Remission)grau (18 % Remission)weiß (90 % Remission)
± 15,0 mm± 14,0 mm± 4,5 mm± 4,0 mm200...1000 mm
± 16,0 mm± 14,5 mm± 6,0 mm± 4,5 mm1000...2000 mm
± 24,0 mm± 23,5 mm± 14,5 mm± 13,5 mm2000...4000 mm
± 31,0 mm± 29,0 mm± 21,0 mm± 19,0 mm4000...6000 mm
--± 47,0 mm--± 37,0 mm6000...10000 mm
Tastweite auf Schwarz (6 % Remission) <= 4000 mm
Die Werte gelten für
- konstante Umweltbedingungen: 23 °C / 960 hPa
- Fremdlicht auf dem Objekt max.: 8 klx
- minimale Einschaltdauer in Minuten: 10
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — Technische Änderungen behalten wir uns ohne Ankündigung vor! — DE — O1D100 — 05.10.2010
Optische Sensoren
O1D100