Safety Information
Attachment 1
www.tuv.com Page 1 of 6 Report No.: 50250100 001
Plug National Deviation evaluated based on UL1310
43 - Direct Plug-In Blade Securement Test
Model
: MZ30PD
Displacement (mm)
Blade 1
Blade 2
Grounding Pin
Blade 1 and 2
Pin holder
type: PC-6610
, mfr.:
CHI MEI CORPORATION
0.20 0.20 -- 0.15
Note
:
1) The blades did not loosen by more than 2.4 mm or pull out.
44 - Direct Plug-In Security of Input Contacts
Model:
MZ30PD
Displacement (mm)
Blade 1
Blade 2
Both Blades
MZ30PD
(before 6000 cycles)
0.1 0.1 0.1
MZ30PD
(after 6000 cycles)
0.25 0.25 0.2
Not
e:
1) The blades did not loosen to a degree that would introduce a risk of a fire or an electric shock.
44.2- Input Blade Endurance
Input blades were retracted for 6000 cycles
Following the cycling and temperature tests the sample was subjected
to the Blade Secureness Test and Input Contacts Security Test.
No hazard
Thermocouple Location
Maximum Temperature (°C)
Before Cycling After Cycling
Pin holder
type: PC-
6610, mfr.: CHI MEI
CORPORATION
64.8 69.0
Ambient 26.7 26.4
46.5 - Direct Plug-In Resistance to Crushing
Model: MZ30PD
Observations
Pin holder
type: PC-6610
, mfr.:
CHI MEI CORPORATION
No damage
Note: 1) There was no splitting, cracking or shattering of the enclosure that would expose internal wiring
or hazardous live parts.