Safety Information

www.tuv.com
Page 39 of 61
Report No.: 50250100 001
TRF No. IEC60950_1F
1.6.2
TABLE: Electrical data (in normal conditions)
P
U (V/Hz)
I (A)
Irated (A)
P (W)
Fuse #
Ifuse (A)
Condition/status
90V/50Hz
0.381
--
19.0
F1
0.381
Loaded with 5Vdc, 3A.
90V/60Hz
0.374
--
19.1
F1
0.374
100V/50Hz
0.356
0.6
19.0
F1
0.356
100V/60Hz
0.346
0.6
19.0
F1
0.346
240V/50Hz
0.159
0.6
18.9
F1
0.159
240V/60Hz
0.168
0.6
19.0
F1
0.168
264V/50Hz
0.147
--
19.1
F1
0.147
264V/60Hz
0.157
--
19.1
F1
0.157
90V/50Hz
0.592
--
32.5
F1
0.592
Loaded with 9Vdc, 3A.
90V/60Hz
0.622
--
32.6
F1
0.622
100V/50Hz
0.550
0.6
32.3
F1
0.550
100V/60Hz
0.565
0.6
32.4
F1
0.565
240V/50Hz
0.274
0.6
31.9
F1
0.274
240V/60Hz
0.292
0.6
32.0
F1
0.292
264V/50Hz
0.254
--
32.0
F1
0.254
264V/60Hz
0.261
--
32.1
F1
0.261
90V/50Hz
0.640
--
35.2
F1
0.640
Loaded with 12Vdc, 2.5A.
90V/60Hz
0.669
--
35.3
F1
0.669
100V/50Hz
0.590
0.6
34.9
F1
0.590
100V/60Hz
0.609
0.6
35.0
F1
0.609
240V/50Hz
0.307
0.6
34.4
F1
0.307
240V/60Hz
0.314
0.6
34.5
F1
0.314
264V/50Hz
0.274
--
34.6
F1
0.274
264V/60Hz
0.281
--
34.6
F1
0.281
90V/50Hz
0.627
--
35.2
F1
0.627
Loaded with 15Vdc, 2A.
90V/60Hz
0.644
--
35.2
F1
0.644
100V/50Hz
0.571
0.6
34.9
F1
0.571
100V/60Hz
0.590
0.6
35.0
F1
0.590
240V/50Hz
0.281
0.6
34.4
F1
0.281
240V/60Hz
0.288
0.6
34.4
F1
0.288
264V/50Hz
0.253
--
34.6
F1
0.253
264V/60Hz
0.264
--
34.5
F1
0.264
90V/50Hz
0.620
--
34.1
F1
0.620
Loaded with 20Vdc, 1.5A.
90V/60Hz
0.635
--
33.9
F1
0.635
100V/50Hz
0.566
0.6
33.8
F1
0.566