Safety Information
www.tuv.com
Page 26 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
5.1.2
Configuration of equipment under test (EUT)
EUT has only one mains
connection.
P
5.1.2.1
Single connection to an a.c. mains supply
P
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c.
mains supply
N/A
5.1.3
Test circuit
Equipment of figure 5A used.
P
5.1.4
Application of measuring instrument
Using measuring instrument in
annex D.
P
5.1.5
Test procedure
The touch current was
measured from mains to DC
output connector and to a 100
mm
´ 200 mm metal foil
wrapped on accessible non-
conductive parts (plastic
enclosure).
P
5.1.6
Test measurements
(see appended table 5.1)
P
Supply voltage (V) ......................................... :
¾
Measured touch current (mA) .......................... :
¾
Max. Allowed touch current (mA) ..................... :
¾
Measured protective conductor current (mA) ...... :
¾
Max. Allowed protective conductor current (mA) .. :
¾
5.1.7
Equipment with touch current exceeding 3,5 mA
Touch current does not exceed
3.5mA.
N/A
5.1.7.1
General ........................................................ :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
No TNV.
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication netw
ork or to a cable
distribution system
N/A
Supply voltage (V) ......................................... :
¾
Measured touch current (mA) .......................... :
¾
Max. Allowed touch current (mA) ..................... :
¾
5.1.8.2
Summation of touch currents from
telecommunication networks
N/A
a) EUT with earthed telecommunication ports .... :
N/A