Safety Information
www.tuv.com
Page 25 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
Conditioning temperature (
°
C), time (weeks)....... :
¾
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
No excessive temperatures.
No easily burning materials
employed. Fire enclosure
provided.
P
Method 1, selection and application of components
wiring and materials
(see appended table 4.7)
P
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
See below.
P
4.7.2.1
Parts requiring a fire enclosure
With having the following parts
▪ Components in primary
▪ Components having
unenclosed arcing parts at
hazardous voltage or energy
level
▪ Ins
ulated wiring
The fire enclosure is required.
P
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3
Materials
P
4.7.3.1
General
See below
P
4.7.3.2
Materials for fire enclosures
V-0 fire enclosure used.
P
4.7.3.3
Materials for components and other parts outside
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
PCB rated V-1. See appended
table 1.5.1.
Internal components except
small parts are V-2 or better.
P
4.7.3.5
Materials for air filter assemblies
No air filters provided.
N/A
4.7.3.6
Materials used in high-voltage components
No high voltage components
provided.
N/A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
P
5.1
Touch current and protective conductor current
P
5.1.1
General
See sub-clauses 5.1.2 to
5.1.6.
P