Safety Information
www.tuv.com
Page 24 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
4.4.5.1
General
N/A
Not considered to cause pain or injury. A)……….:
N/A
Is considered to cause pain, not injury. B) ………:
N/A
Considered to cause injury. C) ………:
N/A
4.4.5.2
Protection for users
N/A
Use of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning …………………………:
N/A
4.5
Thermal requirements
P
4.5.1
General
Equipment loaded with rated
output current.
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ................... :
(see appended table 1.6.2)
¾
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ........................... :
Phenolic bobbin material used
in
transformer T1 which is
acceptable without test. For
other parts, see appended
table 4.5.5.
P
4.6
Openings in enclosures
P
4.6.1
Top and side openings
No openings except opening
of
AC plug
which is covered by
AC plug
and plug
holder of top
enclosure. Remaining opening
<1mm.
P
Dimensions (mm) .......................................... :
¾
4.6.2
Bottoms of fire enclosures
No openings except one USB
output.
P
Construction of the bottom, dimensions (mm) .... :
¾
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) .......................................... :
¾
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A