Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
4.2.6
Drop test; height (mm) ..................................... :
The power supply has been
subjected to 3 drops from 1 m
height on a hard wooden
surface.
P
4.2.7
Stress relief test
After the test at temperature of
116
°C
, no shrinkage, distortion
or loosening of any enclosure
part was noticeable on the
equipment.
P
4.2.8
Cathode ray tubes
No CRT in the unit.
N/A
Picture tube separately certified ........................ :
N/A
4.2.9
High pressure lamps
No high pressure lamp
provided.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ...... :
Not wall or ceiling mounted
equipment.
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
Edges and corners of the
enclosure are rounded.
P
4.3.2
Handles and manual controls; force (N) ........... :
No handles or controls
provided.
N/A
4.3.3
Adjustable controls
No such controls provided.
N/A
4.3.4
Securing of parts
Mechanical fixings in such a
way designed that they will
withstand mechanical stress
occurring in
normal use.
P
4.3.5
Connection by plugs and sockets
No mismatch of connectors
either not possible or does not
result in any hazard.
P
4.3.6
Direct plug-in equipment
See below.
P
Torque ......................................................... :
0.025Nm.
¾
Compliance with the relevant mains plug standard
................................
................................
.... :
The dimension and
construction
of
plug portion for
adapter
was tested and in
compliance with
UL 1310.
P
4.3.7
Heating elements in earthed equipment
No heating elements provided.
N/A
4.3.8
Batteries
No batteries provided.
N/A
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
N/A
- Reverse charging of a rechargeable battery
N/A