Safety Information
www.tuv.com
Page 20 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
Mass of equipment (kg), pull (N) ......................:
¾
Longitudinal displacement (mm) .......................:
¾
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
Diameter or minor dimension D (mm); test mass (g)
.....................................................................:
¾
Radius of curvature of cord (mm) .......................:
¾
3.2.9
Supply wiring space
Not permanent connection or
non
-
detachable power cord
type.
N/A
3.3
Wiring terminals for connection of external conductors
N/A
3.3.1
Wiring terminals
N/A
3.3.2
Connection of non-detachable power supply cords
N/A
3.3.3
Screw terminals
N/A
3.3.4
Conductor sizes to be connected
N/A
Rated current (A), cord/cable type, cross-sectional
area (mm
2
) .....................................................:
¾
3.3.5
Wiring terminal sizes
N/A
Rated current (A), type, nominal thread diameter
(mm) ............................................................:
¾
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8
Stranded wire
N/A
3.4
Disconnection from the mains supply
P
3.4.1
General requirement
See below.
P
3.4.2
Disconnect devices
AC plug
P
3.4.3
Permanently connected equipment
Not permanently connected
equipment.
N/A
3.4.4
Parts which remain energized
When AC plug is disconnected
no hazardous voltage in the
equipment.
P
3.4.5
Switches in flexible cords
None
N/A
3.4.6
Number of poles – single-phase and d.c.
equipment
Plug disconnects both poles
simultaneously.
P
3.4.7
Number of poles – three-phase equipment
Single phase equipment.
N/A