Safety Information

www.tuv.com
Page 19 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
3.1.3
Securing of internal wiring
The internal wires are secured
by
soldering and glue
on PCB,
so that a loosening of the
terminal connection is unlikely.
P
3.1.4
Insulation of conductors
The insulation of the individual
conductors suitable for the
application and the working
voltage.
P
3.1.5
Beads and ceramic insulators
Not used.
N/A
3.1.6
Screws for electrical contact pressure
No such screws provided.
N/A
3.1.7
Insulating materials in electrical connections
For enclosure in contact with
plug pin contacts
contact
pressure is not transmitted
through insulating material.
P
3.1.8
Self-tapping and spaced thread screws
Not used.
N/A
3.1.9
Termination of conductors
All conductors are reliable
secured. See also 3.
1.3.
P
10 N pull test
Force of 10 N applied to the
termination points of the
conductors.
P
3.1.10
Sleeving on wiring
N/A
3.2
Connection to a mains supply
P
3.2.1
Means of connection
See below.
P
3.2.1.1
Connection to an a.c. mains supply
The adaptor provided with a
mains plug.
P
3.2.1.2
Connection to a d.c. mains supply
Only a.c. mains supply.
N/A
3.2.2
Multiple supply connections
Only for one mains connection.
N/A
3.2.3
Permanently connected equipment
Unit is not a permanently
connected equip
ment.
N/A
Number of conductors, diameter of cable and
conduits (mm) ................................................:
¾
3.2.4
Appliance inlets
No such component used.
N/A
3.2.5
Power supply cords
N/A
3.2.5.1
AC power supply cords
N/A
Type .............................................................:
¾
Rated current (A), cross-sectional area (mm
2
),
AWG ............................................................:
¾
3.2.5.2
DC power supply cords
AC Source.
N/A
3.2.6
Cord anchorages and strain relief
N/A