Safety Information

www.tuv.com
Page 17 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
b) Transients from a telecommunication network :
N/A
2.10.4
Creepage distances
See appended table 2.10.3
and 2.10.4.
P
2.10.4.1
General
CTI rating for all materials of
minimum 100.
P
2.10.4.2
Material group and comparative tracking index
P
CTI tests ........................................................ :
Material group IIIb is assumed
to be used.
¾
2.10.4.3
Minimum creepage distances
(see appended table 2.10.3
and 2.10.4)
P
2.10.5
Solid insulation
Electric strength test applied
P
2.10.5.1
General
See below.
P
2.10.5.2
Distances through insulation
(see appended table 2.10.5)
P
2.10.5.3
Insulating compound as solid insulation
No such construction used.
N/A
2.10.5.4
Semiconductor devices
No such devices.
N/A
2.10.5.5.
Cemented joints
No such construction.
N/A
2.10.5.6
Thin sheet material General
P
2.10.5.7
Separable thin sheet material
Used in transformer T1.
P
Number of layers (pcs) ..................................... :
2 layers for reinforced
insulation
¾
2.10.5.8
Non-separable thin sheet material
Not such material
N/A
2.10.5.9
Thin sheet material standard test procedure
N/A
Electric strength test
¾
2.10.5.10
Thin sheet material alternative test procedure
(see appended table 2.10.5)
P
Electric strength test
(see appended table 5.2)
¾
2.10.5.11
Insulation in wound components
Approved triple insulated wire
used in T1.
P
2.10.5.12
Wire in wound components
P
Working voltage ............................................. :
P
a) Basic insulation not under stress ................... :
N/A
b) Basic, supplementary, reinforced insulation ..... :
Wire complies to Annex U,
three layers insulation.
P
c) Compliance with Annex U ............................. :
P
Two wires in contact inside wound component;
angle between 45
° and 90°
.............................. :
Physical separation provided
by insulating tube.
P
2.10.5.13
Wire with solvent-based enamel in wound
components
No such construction.
N/A
Electric strength test
¾