Safety Information

www.tuv.com
Page 15 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
2.8
Safety interlocks No safety interlocks used
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
Protection against extreme hazard
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches, relays and their related circuits
N/A
2.8.7.1
Separation distances for contact gaps and their
related circuits (mm) ....................................... :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
2.9
Electrical insulation
P
2.9.1
Properties of insulating materials
Natural rubber, asbestos or
hygroscopic material not used.
P
2.9.2
Humidity conditioning
Performed at 30 °C, 93% R.H.
for 48
h.
P
Relative humidity (%), temperature C) .............:
See above.
¾
2.9.3
Grade of insulation
See above.
P
2.9.4
Separation from hazardous voltages
The adequate levels of safety
insulation provided and
maintained to comply with the
requirements of this standard.
P
Method(s) used ..............................................:
SELV separated from primary
by reinforced or double
insulation.
¾
2.10
Clearances, creepage distances and distances through insulation
P
2.10.1
General
See 2.10.3, 2.10.4 and 2.10.5.
P
2.10.1.1
Frequency ..................................................... :
30-60kHz generated internally
P
2.10.1.2
Pollution degrees ............................................ :
2
P
2.10.1.3
Reduced values for functional insulation
Considered
P
2.10.1.4
Intervening unconnected conductive parts
Considered
P
2.10.1.5
Insulation with varying dimensions
No such transformer used.
N/A