Safety Information

www.tuv.com
Page 13 of 61
Report No.: 50250100 001
IEC 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60950_1F
Measured voltage (V) ....................................... :
<450Vpeak
¾
Measured circuit capacitance (nF or µF) ............. :
CY1= 470pF
¾
2.4.3
Connection of limited current circuits to other
circuits
Output circuit as limited current
circuit connected to primary via
bridging capacitors (CY1).
P
2.5
Limited power sources
P
a) Inherently limited output
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
A regulating network limits the
output in compliance with
table 2B both under normal
operating conditions and after
any single fault.
P
Use of integrated circuit (IC) current limiters
No such IC used
N/A
d) Overcurrent protective device limited output
N/A
Max. Output voltage (V), max. Output current (A),
max. Apparent power (VA) ................................:
(see appended table 2.5)
¾
Current rating of overcurrent protective device (A) .:
¾
2.6
Provisions for earthing and bonding Class II equipment
N/A
2.6.1
Protective earthing
N/A
2.6.2
Functional earthing
N/A
2.6.3
Protective earthing and protective bonding
conductors
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG .............................................................:
¾
2.6.3.3
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area (mm
2
),
AWG .............................................................:
¾
Protective current rating (A), cross-sectional area
(mm
2
), AWG ...................................................:
¾
2.6.3.4
Resistance of earthing conductors and their
terminations; resistance (
W
), voltage drop (V), test
current (A), duration (min) .................................:
N/A
2.6.3.5
Colour of insulation ..........................................:
N/A
2.6.4
Terminals
N/A