User Manual
TANK-820 Embedded System
Page 76
Enabled DEFAULT
Enable the serial port
Change Settings [Auto]
Use the Change Settings option to change the serial port IO port address and interrupt
address.
Auto DEFAULT
The serial port IO port address and interrupt address
are automatically detected.
IO=2D8h;
IRQ=10
Serial Port I/O port address is 2D8h and the interrupt
address is IRQ10
IO=2C0h;
IRQ=10, 11
Serial Port I/O port address is 2C0h and the interrupt
address is IRQ10, 11
IO=2C8h;
IRQ=10, 11
Serial Port I/O port address is 2C8h and the interrupt
address is IRQ10, 11
IO=2D0h;
IRQ=10, 11
Serial Port I/O port address is 2D0h and the interrupt
address is IRQ10, 11
IO=2D8h;
IRQ=10, 11
Serial Port I/O port address is 2D8h and the interrupt
address is IRQ10, 11
IO=2E0h;
IRQ=10, 11
Serial Port I/O port address is 2E0h and the interrupt
address is IRQ10, 11
Device Mode [RS422/485]
The Device Mode shows Serial Port 5 provides RS-422/485 communications.